AIR HYGIENE INTERNATIONAL INC. operates mobile laboratories that
can be brought onto your site to perform stack emission testing.
AIR HYGIENE labs are equipped with state-of-the-art equipment to
perform real-time pollutant monitoring to generate accurate test
results. AIR HYGIENE typically generates reports on-site, so clients
know that they are in regulatory compliance before we leave the
site. Testing capabilities include:
NOx,
NO, NO2 with Thermo 42H (EPA Method 7e & 20)
- CO with Thermo 48C (EPA Method 10)
- SO2 with API 100AH (EPA Method
6c)
- THC & NMHC with Thermo 51 (EPA Method
25a)
- Oxygen with M&C PMA-22 (EPA Method
3a & 20)
- CO2 (EPA Method 3a & 20)
- Ambient Conditions - Temperature, % Relative
Humidity, and Barometric Pressure
- Moisture with Apex impingers & meter
box* (EPA Method 4)
- BTEX & Hexane with Sensidyne flow
meter* (EPA Method 18)
- Formaldehyde with Apex impingers &
meter box* (Acetylacetone Method)
- Particulate, PM-10, PM-2.5 with Apex isokinteic
sampling train* (EPA Method 5 & 201a)
*manual methods that can be performed simultaneously with instrument
testing
AHI offers these services for the following sources:
Reciprocating
Internal Combustion Engines
- Natural Gas Fired Turbines (NSPS Subpart
GG required)
- Incinerators
- Heaters
- RATA Testing (Relative Accuracy Test Audits
for CEMS, and PEMS)
- Sulfur Recovery Units
- Amine Treating Units
- Flares
- Boilers
- Fluidized Catalytic Cracking Units
|